Organizational and technological solutions for eliminating cracks in reinforced concrete foundation slabs

Abstract

Organizational and technological solutions for eliminating cracks in reinforced concrete foundation slabs

Zhadanovskiy B. V., Pahomova L. A., Krayushkin M. V., Rachkovskaia E. V.

Incoming article date: 26.12.2023

In order to negate the loss of strength, that can lead to collapse of constructions, we should take measures to prevent cracking. Every crack emersion in reinforced concrete indicates that the accumulated stress has been released in this area of the structure. The cause of cracks are internal tensile stresses that can occur due to internal processes in the element and from external loads on the structure. It is possible to eliminate cracks that have already appeared with the help of repair compounds that fill the volume of cracks in various ways. Injection, as one of the solutions, will help to maintain the strength and durability of the structure.

Keywords: cracking, concrete, reinforced concrete slab, crack, defect, deformation, strength, soil, repair compound, foundation, foundation slab, injection